HDI Manufacturer | HDI Factory | High Quality HDI Products – chemhdi.com Knowledge 5 major issues that are easily overlooked in the construction of waterproof gypsum mortar

5 major issues that are easily overlooked in the construction of waterproof gypsum mortar

The anti-seepage of exterior walls is one of the important issues that need to be solved urgently in today’s building construction. Various new wall materials (such as concrete hollow blocks, aerated concrete blocks, etc.) are widely used, but new wall materials generally have the disadvantage of poor impermeability. Therefore, effective measures must be taken to prevent leakage in building exterior walls. In the construction of exterior walls of high-rise buildings, quality problems such as cracks, cracks, hollowing, and shedding of waterproof gypsum mortar layers caused by improper construction operations can be summarized as follows: 1. Layered scraping is not carried out as required

Under normal circumstances, according to the construction requirements of waterproof gypsum mortar, scraping should generally be carried out in 2 to 3 times. However, in order to make progress, construction units often use one-pass survival coating. Construction method.

2. The base layer is not treated as required

The outer frame pipe holes and holes are not blocked several times from the inside to the outside; there is dust and dirt on the wall surface; the wall is too dry , not fully moistened. When scraping is applied under such conditions, the moisture in the mortar will be quickly absorbed by the base layer, which will inevitably affect the strength of the waterproof gypsum mortar.

3. The proportion of waterproof gypsum mortar is incorrect

The construction is not carried out according to the gypsum mortar proportion required by the design and specifications. The waterproof gypsum mortar cannot fully exert its performance and is waterproof and crack-resistant. Problems arise.

4. Add water after the mortar has hardened and use it

Waterproof gypsum mortar stipulates that the prepared mortar must be used up within 45 minutes, and water must not be added after the mortar hardens and used again.

5. Poor maintenance after construction

After the waterproof gypsum mortar hardens, it needs to be sprinkled and cured. After construction, the layer is exposed to the air for a long time and is affected by temperature differences and air drying, causing the gypsum mortar surface layer to shrink and crack. </p

This article is from the Internet, does not represent the position of Toluene diisocyanate reproduced please specify the source.https://www.chemhdi.com/archives/14549

author:

Previous article
Next article
Contact Us

Contact us

+86 - 152 2121 6908

Online consultation: QQ交谈

E-mail: sales@newtopchem.com

Working hours: Monday to Friday, 9:00-17:30, closed on holidays
Follow wechat
Scan wechat and follow us

Scan wechat and follow us

Follow Weibo
Back to top
Home
E-mail
Products
Search
zh_CNChinese